ACD/MS Manager: Available Branches 


 
Request more information
   

Overview

Product Details:
   

Input/Output

Processing Features

Technical Info

What's New

Resources:
   

Application Notes

Technical Notes

Demo Movies

Catalog

Brochure

Useful Links

Related Products:
   

Processor vs. Manager

MS Manager

MS Manager Suite

IntelliXtract

MS Fragmenter

Chromatography Products

ACD/MS Processor

What's New

Version 10.0 to 11.0

Advancements to Fragment Assignment
  • Negative ion fragmentations added
  • Additional fragmentation reactions for positive ions have been added to the fragmentation rule set
Improved Ease of Use
  • New shortcuts for displaying mass chromatograms
  • Better synchronization of two or more data files
  • Ability to dock the Table of Mass Chromatograms
  • Easier to resize the Table of Mass Chromatograms
  • New commands for reviewing the Table of Mass Chromatograms-Keep All Records Expanded, Keep All Records Selected, and Remember All Selected
Updates to Supported File Types
  • New Shimadzu GC/MS (*.qgd) data import filter has been added
  • Support for Varian *.xms data files
  • Conversion of NIST SDfile libraries, including structures and mass spectra, to separate *.esp files via the MS File Splitter/Converter
  • New Agilent LCMS 6000 (*.bin) import filter that supports data from Agilent 6000 series instruments
Enhancements to Ion Presence Labeling
  • Specify a retention time range for ion presence labeling lists
Improved LC/UV (PDA, DAD) Data Processing
  • Set the minimal wavelength for processing
  • Exclude the solvent front from LC/UV data processing
  • New virtual separation parameter to help resolve overlapping chromatographic components
  • 2D-peak picking calculation results output to Table of Peaks
  • Better quality peak picking
  • Easier transfer of LC/UV data to ACD/Matrix
New Macro Commands
  • Automatically display all mass chromatograms at once within the chromatogram window with new SetMCTableAllExpandedSelected command
  • Average and subtract mass spectra over specific retention time ranges with new Combine command
Other New Features
  • Mass column in Table of Formulae renamed Monoisotopic Mass
  • New default settings for AutoAssign function
  • New default display settings

Download a PDF copy of the expanded details on What's New with ACD/MS Processor, or contact your Account Manager or Distributor.

Version 9.0 to 10.0

Improved Fragment Assignment
  • Neutral loss reactions added to the fragmentation rule set
  • Additional ionization and fragmentation reactions have been added to the fragmentation rule set
Enhancements to Formula Generator
  • Ionization parameters added to Formula Generator; output the formula for the neutral or charged form
  • Generate the neutral formula from adduct ion peaks in the mass spectrum
Advancements to LC/UV (DAD, PDA) data processing
  • Peak picking for LC/UV datasets
  • Baseline correction for LC/UV datasets allows you to subtract the solvent background, and extract accurate UV-Vis spectra for chromatographic peaks
  • Easier transfer of peak information (e.g., label, chemical structure) with the manual peak matching tool
New Chromatographic Data Support Features
  • Automatic import of chromatographic parameters for MassLynx and Agilent LC/MS data Chromatographic parameters are stored in the new HPLC Parameters form, which may also be manually updated
  • Export the TIC, now along with peak labels, retention times, and structures to ChromManager
  • Select and label individual mass chromatogram peaks, which are now added to the Table of Peaks for the whole dataset
  • Manually edit peak names in the Table of Peaks
Updates to Supported File Types:
  • Improved JCAMP file support now allows import of ionization information
  • Improved import of previously processed Waters MassLynx data
  • New *.Wiff data import filter added to the MS File Splitter/Conversion utility
  • Support for Waters Millennium LC/MS files
  • Support for uniquely named Agilent and Bruker *.yep files (i.e., other names than Analysis.yep)
  • Support for Thermo Xcalibur version 2.0
  • Support for Waters MassLynx version 4.1
  • Enhanced support of AB MDS Sciex Analyst 4.1.1 files
Other New Features
  • Convert profile data to centroid data for LC/MS datasets, and single mass spectra. This is also available for macro automation
  • Improved mass chromatogram display
  • Save and load Ion Presence labeling lists

Version 8.0 to 9.0

I) Improved Fragment Assignment:

  • Assign ion clusters, including different isotopes of the same fragment.
  • Evaluate the quality of the fragment assignment using the Assignment Quality Index (AQI).
  • Improved N-oxide fragmentation scheme.

II) Enhancements to Mass Chromatogram Display and Processing:

  • Increased speed of processing and display of mass chromatograms.
  • Additional peak picking options:
    • Threshold area value.
    • m/z range.
  • Mass chromatogram smoothing options:
    • Apply FFT or Savitzky-Golay smoothing functions.
  • Identify and label relevant mass chromatogram peaks with ACD/Ion Presence™:
    • Find and label mass chromatogram peaks with a specific mass or mass difference from a reference mass.

III) Compare Mass Spectra using Advanced Spectral Subtraction Options and Spectral Mirroring:

  • Expanded spectral subtraction options:
    • Apply m/z based, intensity based, or interpolation subtraction to subtract the relative intensities of ions between spectra.
    • Use Boolean subtraction to remove common peaks between spectra.
    • Remove the major peaks within a spectrum using single peak subtraction.
  • Spectral Mirroring:
    • Display two mass spectra using a common x-axis. One is displayed above the axis, and the other is displayed below.

IV) Updates to Supported File types:

  • New file formats supported by ACD/MS Manager are:
    • Import LC/MS data from Agilent LC TOF wiff files.
    • Import LC(GC)/MS data from JEOL K9 files.
    • Import a single spectrum or LC(GC)/MS data files from MasCom MASPECII32 files.
    • Import or export LC(GC)/MS data in MATLAB/Eigenvector DSO format.
    • Import LC(GC)/MS data from MDS SCIEX Analyst, any data type.

V) Other New Features:

  • Ease-of-Use Features:
    • Select from pre-set relative chromatogram and mass spectrum window pane sizes.
    • Easier creation of averaged and combined spectra.
    • Table of Mass Chromatograms can now be sorted using any number of columns.
  • Attach a mass value to a Markush structure.
TOP

This page was last updated 02 November 2007
 

  Products | Solutions | Support
Online Services | Resources
About Us | Downloads | Events
Site Map | Contact Us
 

 
Copyright © 1996 - 2008 Advanced Chemistry Development     All rights reserved